CIENA-PRO-SOFTWARE-MIB DEFINITIONS ::= BEGIN

IMPORTS
    cienaPro
        FROM CIENA-SMI
    DateTime
        FROM CIENA-PRO-TYPES-MIB
    MODULE-IDENTITY, OBJECT-TYPE
        FROM SNMPv2-SMI
    TEXTUAL-CONVENTION
        FROM SNMPv2-TC;

cienaProSoftwareMIB MODULE-IDENTITY
    LAST-UPDATED "202010010000Z"
    ORGANIZATION
        "Ciena Corporation"
    CONTACT-INFO
        "Web: http://www.ciena.com
         Postal:   7035 Ridge Road
                   Hanover, Maryland 21076
                   U.S.A
         Phone:    +1 800-921-1144
         Fax:      +1 410-694-5750"
    DESCRIPTION
        "This module defines software upgrade support for Ciena Platform's."
    REVISION    "202010010000Z"
    DESCRIPTION
        "Initial Revision."
    ::= { cienaPro 2 }

--
-- Textual Conventions
--
UpgradeOpState ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
        "Software upgrade operational state."
    SYNTAX      INTEGER {
        unknown(0),
        idle(1), 
        loadInProgress(2),
        loadComplete(3),
        loadFailed(4),
        invokeInProgress(5),
        invokeComplete(6),
        invokeFailed(7),
        installationInProgress(8),
        installationComplete(9),
        installationFailed(10),
        commitInProgress(11),
        commitComplete(12),
        commitFailed(13),
        cancelInProgress(14),
        cancelComplete(15),
        cancelFailed(16),
        deleteInProgress(17),
        deleteComplete(18),
        deleteFailed(19),
        automaticUpgradeInProgress(20),
        automaticUpgradeComplete(21),
        automaticUpgradeFailed(22),
        moduleColdRestartRequired(23),
        componentUpgradeInProgress(24),
        componentUpgradeComplete(25),
        componentUpgradeFailed(26),
        deliveryInProgress(27),
        deliveryComplete(28),
        deliveryFailed(29)
    }

UpgradeOperation ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
        "Software upgrade operation"
    SYNTAX      INTEGER {
        unknown(0),
        none(1),
        softwareInstall(2),
        softwareDeliver(3),
        softwareLoad(4),
        softwareActivate(5),
        softwareCommit(6),
        softwareCancel(7),
        softwareDelete(8),
        autoUpgrade(9)
    }
               
OperationResultType ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
        "Software upgrade result"
    SYNTAX      INTEGER {
        ok(0), 
        failed(1),
        unknownError(2),
        timeout(3),
        packageDeliveryFailure(4),
        packageValidationFailure(5),
        insufficientDiskSpace(6),
        packageExtractionFailure(7),
        systemError(8),
        dependentServiceError(9),
        packageInformationUnavailable(10),
        upgradeVersionUnknown(11),
        authenticationFailure(12),
        fileNotFound(13),
        fileTransferFailure(14),
        invalidUri(15),
        invalidState(16),
        dataConversionFailure(17),
        licenseCheckFailure(18)
    }

--
-- Node definitions
--

cienaProSoftware OBJECT IDENTIFIER
    ::= { cienaProSoftwareMIB 1 }

cienaProSoftwareUpgradeOperationalState OBJECT-TYPE
    SYNTAX      UpgradeOpState
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Current software manager state.
         Examples: <op>-in-progress, <op>-complete, <op>-failed or Idle."
    ::= { cienaProSoftware 1 }

cienaProSoftwareEntityReportedState OBJECT-TYPE
    SYNTAX      UpgradeOpState
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Current state reported by the managed upgrade entity.
         Examples: <op>-in-progress, <op>-complete, <op>-failed or Idle."
    ::= { cienaProSoftware 2 }

cienaProSoftwareOperationInProgress OBJECT-TYPE
    SYNTAX      UpgradeOperation
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Current software manager operation in progress, if applicable."
    ::= { cienaProSoftware 3 }

cienaProSoftwareOperationStartTimestamp OBJECT-TYPE
    SYNTAX      DateTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Timestamp when the current software manager operation in progress started.
         (Not supported in this software release version)."
    ::= { cienaProSoftware 4 }

cienaProSoftwareLastOperation OBJECT-TYPE
    SYNTAX      UpgradeOperation
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Timestamp when the current software manager operation in progress started.
         (Not supported in this software release version)."
    ::= { cienaProSoftware 5 }

cienaProSoftwareLastOperationResult OBJECT-TYPE
    SYNTAX      OperationResultType
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Result of the last completed software manager operation."
    ::= { cienaProSoftware 6 }

cienaProSoftwareLastOperationResultStr OBJECT-TYPE
    SYNTAX      OCTET STRING
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Result description details of the last completed software manager operation."
    ::= { cienaProSoftware 7 }

cienaProSoftwareLastOperationStartTimestamp OBJECT-TYPE
    SYNTAX      DateTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Timestamp when the Timestamp when the last software manager operation had started."
    ::= { cienaProSoftware 8 }

cienaProSoftwareLastOperationEndTimestamp OBJECT-TYPE
    SYNTAX      DateTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Timestamp when the last software manager operation completed."
    ::= { cienaProSoftware 9 }

cienaProSoftwareCommittedVersion OBJECT-TYPE
    SYNTAX      OCTET STRING
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Last successfully upgraded software release version.
         Format: RLS-xx.yy.zz.bbbb."
    ::= { cienaProSoftware 10 }

cienaProSoftwareActiveVersion OBJECT-TYPE
    SYNTAX      OCTET STRING
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Target software release version which was activated by an upgrade.
         UNKNOWN implies an upgrade is required.
         Format: RLS-xx.yy.zz.bbbb."
    ::= { cienaProSoftware 11 }

cienaProSoftwareUpgradeToVersion OBJECT-TYPE
    SYNTAX      OCTET STRING
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Target software release version of an in-progress upgrade.
         Format: RLS-xx.yy.zz.bbbb."
    ::= { cienaProSoftware 12 }

cienaProSoftwareRunningVersion OBJECT-TYPE
    SYNTAX      OCTET STRING
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Actual software release version that is currently running
         and is expected to match active-version after an upgrade is completed.
         Format: RLS-xx.yy.zz.bbbb."
    ::= { cienaProSoftware 13 }

END -- end of module CIENA-PRO-SOFTWARE-MIB.